The SCSOC provides a streamlined, cell-to-sequencing library service package for Single Cell RNA sequencing (scRNA-seq). It is capable to simultaneously profiling of transcriptomes ranging 500 – 10,000 cells in a single experiment. Different indexing systems are designed to label cell, transcript and sample origin in the sequencing library. This enables multiplexing of different sequencing libraries from multiple samples in the same Next Generation Sequencing (NGS) run. Libraries are Illumina-format compatible.

The service provided by SCSOC includes an initial sample QC check, following by an evaluation of overall quality of sample for fitness to continue run. Single cells are then encapsulated in thousands of Gel Bead-in Emulsion (GEM) droplets, where cells are lysed and mRNA molecules reverse transcribed into cDNA. cDNA with specific cell barcodes are then pooled together and subjected to subsequent conventional sequencing library preparation. A final QC is performed on the final sequencing library to ensure sound quality for massively-parallel sequencing.

The SCSOC welcomes interested PIs for experimental troubleshooting, intellectual advices as well as project discussions / collaborations.

Equipment
Countess 3 Cell Counter (Cell viability check and counting)
Light Microscope / Hemocytometer (Manuel cell counting)
Compact cooling centrifuge
10X Controller (Single cell encapsulation)
Chromium iX (Single cell analysis)
PCR workstation
PCRs, thermomixer, vortex, plate centrifuge
Qubit 4 Fluorometer (DNA/RNA library quantification)
NanoString CosMx Spatial Molecular Imager (spatial multiomics single-cell imaging)
3DHistech TMA Master II (create tissue microarray blocks)
Equipment Groups
Equipments
RWD C100 Automated Cell Counter with fluorescence (Cell viability check and counting)
Light Microscope / Hemocytometer (Manuel cell counting)
Compact cooling centrifuge
10X Controller (Single cell encapsulation)
10X Chromium iX Controller (Single cell encapsulation)
10X Visium CytAssist (Spatial profiling)
PCR workstation
PCRs, thermomixer, vortex, plate centrifuge
Qubit 4 Fluorometer (DNA/RNA library quantification)
NanoString CosMx Spatial Molecular Imager (spatial multiomics single-cell imaging)
3DHistech TMA Master II (create tissue microarray blocks)
Boekel Scientific RapidFISH slide hybridization chamber
Service Workflow
Next GEM workflow
Day 1 workflow
Day 2 workflow
Service request

Please contact Dr Joaquim Vong (email: joaquim@cuhk.edu.hk / 39430318) for service request, technical enquiry and project discussion.

For service request, please fill in our Sample submission form.

Service fees include: (please enquire)

✓ Package set: From cell to sequencing library
✓ Cell quality and viability check / basic QC
✓ Sequencing library QC and quantification
✓ Intellectual advices (wet / dry lab)
✓ Troubleshooting

× Sequencing NOT included
× Repeated initial sample QC checks might incur extra charges

Output items

A. Sequencing library
B. QC reports for cDNA and sequencing library
C. Indexing information

The final product is a double-stranded cDNA molecule with sequencing adaptors and 3 different indices (10X barcode: cell info; UMI: transcript info; sample index: sample info). The sequencing library quality is evaluated by running into an Agilent 4200 TapeStation System.

10X Barcode
Source: 10X Genomics

Precautions

Users are required to fill in and sign the “Service Form for Single Cell Omics Core” prior to sample submission
https://webapp.sbs.cuhk.edu.hk/eform/view.php?id=55400

All users MUST declare the nature of sample(s) submitted to SCOC FREE of any bio-hazardous material.

An initial assessment of cell quality will be conducted for the generation of data with optimal quality. Users may take the risk of sub-optimal data quality if the initial cell quality check fails.

Upon service booking, a copy of the confirmed service form will be forwarded to both the end user as well as the corresponding PI.

Initial sample submission evaluation (sample quality, amount, etc) is recommended to optimize sample quality, depending on the sample nature. Potential experimental discussion(s) might be arranged prior to samples submission.

The complete workflow take approximately 2 full working days. As only limited amount of samples can be performed per week, users are encouraged to optimize their sample quality before submission. Service bookings are arranged on a first-come-first-serve basis.

Once the service has started, service charge would be accounted for FULL service package price, as the reagents are on package stock basis. We are pledged to provide our service in a reasonable, efficient manner with quality.

Contacts
Dr Joaquim Vong
Scientific Officer
Ms Chloe Chen
Research Assistant
(EN) LIBSB Room 525